SATO CL608VA Manuel de l'opérateur Page 125

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 256
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 124
Postnet
Command Structure <ESC>BPn...n
n...n = 5 digits (Postnet-32 format)
6 digits (Postnet-37 format)
9 digits (Postnet-52 format)
11 digits (Postnet-62, Delivery Point format)
Example: <ESC>BP123456789
Placement: Immediately preceding the data to be encoded
Default: None
Command Function To print Postnet bar codes
Printer Input
<ESC>A
<ESC>H0100<ESC>V0120<ESC>BP94089
<ESC>H0100<ESC>V0160<ESC>BP123456
<ESC>H0100<ESC>V0200<ESC>BP123456789
<ESC>H0100<ESC>V0240<ESC>BP12345678901
<ESC>Q1<ESC>Z
Printer Output
Special Notes 1. If the number of data digits does not match those listed, the
command is ignored.
2. Only numeric data will be accepted.
Section 4. Programming Reference