5.3 Controller Installation, Meto-Logic
1. Open lower Front Door.
2. Locate power strip above main power supply cabinet (see Figure 5-17).
3. Position the Controller in the lower cabinet as shown in Figure 5-15.
4. Connect the monitor AC power cord from the connector panel harness to the Unswitched AC receptacle of
the Printer.
AC Power Strip
Controller
Figure 5-15
!
CAUTION
!
The printer power cord must not be connected until after the controller
has been installed.
!
WARNING
!
Before installation, the Controller power supply voltage selector switch
must be set to the 230V position.